Designed for one-step viral/pathogen detection for the development of both centralised and point of care testing (POCT) workflows.
- High sensitivity to detect low copy RNA and DNA targets in single- and multiplex reactions.
- Single tube, room temperature-stable formulation streamlines automated workflows
- Glycerol-free components for flexible lyophilisation options
- 5X concentration allows increased sample addition in liquid reactions or smaller lyobead formation during manufacturing.
- General purpose reagent manufactured in an ISO 13485-certified facility
Limited time offer - 50% discount off first 1 mL order
RapiDxFire™ Lyo-Flex 1-Step RT-qPCR 5X Master Mix is a convenient, single-tube master mix that provides sensitive and reproducible detection of bacterial and viral pathogens. Optimised for multiplexing with gene-specific primers and BHQ probes, this temperature-stable, glycerol-free, mix is ideal for molecular diagnostic kit manufacturers developing traditional tests for high-throughput, automated workstreams or lyophilised tests for POC devices.
Provided at a 5X concentration without passive reference dye, this robust master mix includes a heat-activated thermostable reverse transcriptase, Taq DNA polymerase, and dNTPs (including dUTP) in a single, Triton-free, glycerol-free buffered solution. Compatible with added Uracil N-Glycolsylase (UNG) to control carryover contamination and/or an RNase inhibitor for template preservation, RapiDxFire Lyo-Flex 1-Step RT-qPCR 5X Master Mix is a versatile component for diagnostic test development. RapiDxFire Lyo-Flex 1-Step RT-qPCR 5X Master Mix is manufactured in an ISO 13485-certified facility and is available in suitable test development sizes to large scale production lots.
RapiDxFire Lyo-Flex 1-Step RT-qPCR 5X Master Mix is a General Purpose Reagent (GPR), labelled For Laboratory Use (FLU). The FLU label statement identifies an in vitro diagnostic medical device in the United States. Outside the United States the FLU statement is equivalent to Research Use Only.
- Concentration: 5X Master Mix
- Storage: Store at -20 °C.
- Master Mix buffer: Glycerol-free and Triton™ X-100-free buffer
- Contaminating activity assays: RapiDxFire™ Lyo-Flex 1-step RT-qPCR 5X Master Mix is free of detectable contaminating DNA exonuclease, DNA endonuclease and RNases.
Sensitive detection of RNA and DNA targets
Figure 1. Broad dynamic range for both RNA and DNA targets. (a) SARS-CoV-2 RNA control (Twist) 10-fold serially diluted from 1x106-1x100 copies per reaction, on which the UltraDx SARS-CoV-2 N1/N2/RnP assay (Biosearch Technologies) was performed (N1/N2:FAM shown) (20 µL total reaction volume). (b) genomic mouse DNA 10-fold serially diluted from 300,000 to 3 copies per reaction on which the Isg20 assay was performed (N1/N2:FAM shown) (20 µL total reaction volume). PCR efficiencies (90%-110%) and R2 values >0.98 for (a) SARS-CoV-2 RNA and (b) genomic mouse DNA assays met PCR criteria.
Enhanced reaction stability at room temperature
Figure 2. Fully assembled reaction mix at room temperature gives stable and sensitive Cq values for all targets for up to 8 hours. Genomic MS2 RNA (100 copies per reaction, 20 µL total reaction volume) tested in triplex with each MS2-region specific BHQ™ Probe assigned a unique fluorophore ((a) R6D1:FAM; (b) R3D3:CAL Fluor Orange 560 (c) R8D1:Quasar 705). RapiDxFire Lyo-Flex 1-Step RT-qPCR 5X Master Mix was tested against Competitor A and Competitor B, according to manufacturer’s recommendations. The lower the Cq value, the more sensitive the detection. A Cq value ≥50 is indicative of no amplification.
Lyo-compatible formulation
Figure 3. Consistent performance of RapiDxFire Lyo-Flex 1-Step RT-qPCR 5X Master Mix post-lyophilisation by Vendor A, supplemented with 4 mM MgCl2. Lyophilised spheres were tested against genomic MS2 RNA 10-fold serially diluted from 1x107-1x102 copies per reaction (20 µL total reaction volume), with each MS2-region specific BHQ Probe assigned a unique fluorophore (R6D1:FAM; R3D3:CAL Fluor Orange 560; R8D1:Quasar 705). (a) pre-lyophilisation and (b) post-lyophilisation amplification curves, tested with the R6D1:FAM assay, and standard curves for all targets, with PCR efficiencies (90%-110%) and R2 values >0.98, meeting PCR criteria.
Lyobeads remain stable at room temperature over time
Figure 4. Lyobead stability demonstrated after 0 and 4 month storage at room temperature (25 °C). Lyobeads (manufactured by Vendor B) were prepared with RapiDxFire Lyo-Flex 1-Step RT-qPCR 5X Master Mix and tested against genomic MS2 RNA 10-fold serially diluted from 1x107-1x102 copies per reaction (20 µL total reaction volume), with each MS2-region specific BHQ Probe assigned a unique fluorophore (R6D1:FAM; R3D3:CAL Fluor Orange 560; R8D1:Quasar 705). (a) 0 month and (b) 4-month time point amplification curves, tested with the R6D1:FAM assay and standard curves for all targets, with PCR efficiencies (90%-110%) and R2 values >0.98, meeting PCR criteria.
For research use only. Not for use in diagnostic procedures. Unless otherwise agreed to in writing, IDT does not intend for these products to be used in clinical applications and does not warrant their fitness or suitability for any clinical diagnostic use. Purchaser is solely responsible for all decisions regarding the use of these products and any associated regulatory or legal obligations.